10
To enable the door alarm after it has been disabled:
1. Lift handset, press # to receive dial tone.
2. Press 6.
3. Receive dial tone.
Alert Tone
The phone and station receives a ringback tone prior
to connection. Default the station receives the tone.
To remove the alert tone:
1. Lift handset, press # and receive dial tone.
2. Press # 1 2 3 # 9.
3. Press 0.
4. Press #.
5. Receive dial tone.
To re-activate the alert tone:
1. Lift handset, press # and receive dial tone.
2. Press # 1 2 3 # 9.
3. Press 1.
4. Press #.
5. Receive dial tone.
Door Detect
Some door alarm contacts are closed when the door is
closed and some are open when the door is closed.
By default, the V-2901A uses door alarm contacts
that are open when the door is closed.
To change this default:
1. Lift handset, press # and hear dial tone.
2. Press # 1 2 3 # 0 1.
3. Press # and receive dial tone.
OPERATION
When the doorplate button is pressed, interrupted ring
voltage from the V-2901A initiates ring-in on the
telephone system and sends a confirmation tone to the
door. When the phone is answered, the ringing is
removed, the phone receives a ringback tone and is
connected to the handsfree speaker.
If the door is equipped with an electric strikeplate, a
code can be dialed from the phone to operate the
relay used to unlock the door. The lock relay will
remain open for a programmed period of time. A
normally open, single-pole push-button switch can
also be connected to the V-2901A to manually
operate the door unlock relay. The lock relay will
remain open as long as the remote button is held
(maximum 99 seconds) plus the programmed period
of time.
After the lock relay has closed, if the door remains
open longer than the programmed time, and a
customer supplied door sensor is provided, an alarm
condition will occur. If on hook, the phone will
begin ringing in a pattern indicating that the door has
failed to close and the UDO (Unauthorized Door
Opening) output goes to ground. When answered,
the phone will receive a momentary warble tone and
will be connected to the station. After hang up, if the
door is not closed, the alarm condition will continue.
When an indication arrives that the door is open
while the door station is inactive, (example: a
break-in) the system waits the programmed period of
time for a confirmation of entry, if the confirmation
of entry is not received, the unauthorized entry alarm
will take place as described previously.
Confirmation of Entry
When a key entry is made (an entry not using the
dialpad or remote button), either the remote button
must be pressed (a confirmation press) within the
programmed period of time after the door is opened
or the telephone can be used to dial the appropriate
confirmation of entry. To confirm an entry by phone,
access the V-2901A and enter door unlock code.
A confirmation press or entering the unlock code via
telephone to signify a legitimate door opening must
take place before the programmed period of time ends
or an alarm condition will occur.
NOTE: The remote button can be used for a
confirmation press or to activate the lock relay
(door unlock).
Exiting without Alarm Activation
1. Lift handset and enter door unlock code or press
manual door unlock push-button.
2. Exit door within the programmed exit delay time.
Exit delay time equals time door unlock relay is
activated after unlock.
Call Out from the Phone
The dedicated single line telephone, C.O. line
position, loop or ground start trunk used with the
V-2901A is dedicated to the door communications
and to features accessed within the V-2901A system.
The phone can be used to access the speaker station
by going offhook or by accessing the C. O. line
position or trunk port that is connected to the
V-2901A. A ringback tone (optional) will be
generated prior to connection to the station.
A telephone connection with the station can be
terminated by hanging up or pressing the # sign.
Comentários a estes Manuais